Right heart catheterization
Things can and do go wrong with the right side of the heart, so it is important to know what normal pressures look like on the right side and how they are measured. This diagram shows the measurement of right-sided pressures by a right heart catheterization. A right heart catheterization can also be used to gauge the preload of the left ventricle, as estimated by the pulmonary capillary wedge pressure, or wedge pressure for short.
Drag the catheter tip, or use the slider, to thread the catheter into the femoral vein and up into the right side of the heart. Along the way, inflate the balloon with the balloon button. Move the catheter, with the balloon inflated, all the way into the pulmonary arteries and watch how the pressure at the tip changes on the monitor.
Key points
The catheter has a small balloon near its tip, and a pressure sensor (pressure gauge), a kind of measuring device, at the tip. The balloon can be inflated with a small air-filled syringe, not shown, attached to the other end of the catheter. The waveform for the measured pressure is shown on the monitor. In real life, the person threading the catheter watches the pressure on a screen like this.
As you start threading the catheter into the body, notice how low the pressure is in the veins. Central venous pressure, the pressure in the large veins leading to the heart, is normally less than 10 mmHg and typically between 3 and 8 mmHg.
As the catheter approaches the heart, the pressure waveform already shows some variation, from the pressure changes as the heart contracts and relaxes. As you push the catheter farther into the heart, the waveform changes again, and the person threading the catheter can follow its progress by these changes.
The balloon is normally inflated as the catheter enters the heart. The balloon then acts like a sail, so the flow of blood carries the catheter tip along its path.
As you move the catheter into the right ventricle, the systolic pressure rises with each contraction of the heart. The right ventricle's pressures normally look like the left ventricle's, only smaller, because less pressure is needed to pump blood through the low resistance of the pulmonary circulation.
The pulmonic valve, also called the pulmonary valve, separates the right ventricle from the pulmonary trunk and pulmonary arteries. Closure of this valve during diastole lets the right ventricle's pressure fall, so the ventricle can fill.
As you move the catheter into the pulmonary trunk and arteries, the waveform changes again. The pressure no longer falls as far during diastole as it did in the right ventricle. On this side of the pulmonic valve, the valve's closure maintains the pressure by preventing blood from flowing back into the right ventricle.
By inflating the balloon and wedging it in a small pulmonary artery, which stops the blood flow in that artery, the pressure beyond the tip of the catheter can be measured. While the balloon is wedged, no blood flows in that artery beyond the balloon. Without flow, there is also no pressure drop (recall that pressure drop = flow × resistance) from the balloon to the structure the vessel leads to, the left atrium. So when the balloon is wedged, the catheter measures a slightly delayed version of the left atrial pressure. The left atrial pressure is a measure of the preload of the left side of the heart, since the left ventricle fills from the left atrium.
The wedge pressure provides useful information. For example, it may be raised in left heart failure, when the left side of the heart is not pumping adequately or does so only at higher filling pressures. The right-sided pressures also give information about blood volume through the central venous pressure, a bit like a fuel gauge that shows how full a car's tank is. For critically ill patients with unstable circulation, a catheter in place on the right side gives a useful gauge of the patient's volume status and of the effects of treatments on the cardiovascular system.
The leg veins are not the only route for a right heart catheterization; the veins of the neck or upper chest can also be used. The pulmonary artery catheter, with its balloon and pressure sensor, is also called a Swan-Ganz catheter, after its inventors, Drs. Swan and Ganz.
Did you know? Werner Forssmann, a German physician, performed the first right heart catheterization in 1929, on himself. He threaded a catheter up through a vein in his arm, then walked to the radiology department, where he advanced the catheter into his right atrium and had X-rays taken that confirmed its position. This was unknown territory, and Forssmann risked his life to carry it out. He published his work and later shared the Nobel Prize for it.
Questions this figure helps answer
The figure explains the physiology behind these questions. It cannot interpret anyone's own catheterization results; a clinician can.
The model behind this figure
The figure shows one typical beat at each place, repeated at a heart rate of 75 beats per minute. The traces have the shapes and pressures of normal catheter tracings, all on one time base. In the right atrium, the a wave, from the atrium's contraction, comes just before the right ventricle's upstroke, and the v wave, from filling while the tricuspid valve is closed, comes after the ventricle's contraction. The wedge trace's a and v waves come later in the beat, delayed on their way from the left atrium to the catheter tip. The tip reads the pressure of the place it is in. In the leg veins the pressure is low and fluctuates very little, and up the inferior vena cava the right atrium's waves grow toward the heart.
The right atrium's pressure is 3 to 6 mmHg with a mean of 4. The right ventricle's is 25/5 mmHg, systolic over end-diastolic: early in diastole it falls to about 1 mmHg, then rises as the ventricle fills. The pulmonary artery's is 25/10 mmHg with a mean of 16, with a small notch where the pulmonic valve closes. The wedge pressure is 8 to 11 mmHg with a mean of 10. These sit within the usual textbook ranges: right atrium 2 to 6, right ventricle 15 to 30 systolic and 2 to 8 at the end of diastole, pulmonary artery 15 to 30 over 4 to 12, and wedge 6 to 12 mmHg.
Breathing, which moves real tracings up and down, is not shown, and the heart rate stays at 75. The path through the heart is drawn as one smooth route; in life the catheter is guided by its waveforms, and sometimes by X-ray. The figure shows a healthy adult lying down; heart failure, pulmonary hypertension and valve disease are not shown.
The figure explains physiology. It is not clinical advice.
Using this figure with an AI assistant
If you use an AI assistant that can see this page, whether it is built into your browser or opens the page in its own browser, you can ask it about this figure, ask it to show you what happens in a particular case, or ask it to take you through one of the Show Me tours. It can work the figure itself, point out its parts, and explain what you see. The rest of this section is for the assistant.
An AI assistant can use this figure in three ways. In a browser with WebMCP, the page offers its actions as tools. In the page's scripts, the same actions are in window.physiologyFigures, with a description of the controls and what they mean, the values shown, the model's limits, the everyday questions the figure helps answer, and the Show Me tours. Both do what the page's slider, balloon button and drag handle do, wait until the figure shows the result, and return the exact values; they can also point out parts of the figure, and move the catheter to a named place. An assistant can also drag the slider and press the button, but then it has to read the results off the screen. The page address always holds a link to the state shown, such as ?place=wedged.