PV loop and preload

Preload is a measure of how well stretched or filled the left ventricle (LV) is just prior to ejection. Left ventricular end diastolic volume (LVEDV) or alternatively left ventricular end diastolic pressure are used as measures of preload.

Drag point B right or left along the curve, or use the slider, to see what effect changes in preload have on stroke volume (SV). In general, more filling gives greater ejection, up to a point. The faded gray loop and bars show the normal cardiac cycle for comparison.

Key points

A useful way of thinking about preload is to consider it as the degree of stretch on the left ventricle's sarcomeres just prior to ejection. Up to a point, more stretch on the sarcomeres leads to greater ejection, that is, an increased stroke volume. You can see this by the increasing SV as you increase preload by dragging point B to the right.

As you drag point B left or right to vary the preload, also watch the ejection fraction (EF), shown by the colored bars and the fraction. EF is the fraction of its volume that the left ventricle ejects during one ejection. For example, if the LV fills with 150 mL of blood and ejects 75 mL of that, the ejection fraction is 50%. In this figure the ejection fraction rises only a little with preload, because stroke volume rises nearly in step with end-diastolic volume.

You can see that the EDPVR curve hooks upward toward the right. This reflects the fact that the heart has limits to its expansion. Beyond a certain point, it takes an increased change in pressure to yield a given change in end diastolic volume.

Looking at changes in LVEDV to assess changes in preload is valid for a given point in time, but as the heart changes over time (for example, undergoes hypertrophy due to a valvular disorder), the same LVEDV may represent a different degree of stretch on the sarcomeres (because there may be more sarcomeres laid end to end, for example) and therefore a different preload.

As an example to illustrate the previous point, consider a chain bracelet made of elastic links. If you stretch the bracelet, each link stretches. The degree of stretch on one link can be inferred by looking at the overall length of the bracelet; these quantities are concordant. If, however, you add more links to the bracelet over time (similar to how the heart muscle adds sarcomeres in series in certain forms of hypertrophy), then for a given bracelet length, each link will be less stretched than before and the bracelet will not snap back as well. In that case, the overall length of the bracelet no longer reflects the amount of stretch on individual links. Preload is more like the stretch of an individual link (sarcomere in the heart) than the overall length of the bracelet. Usually the two go together, but not always.

Did you know? During coronary bypass surgery, the stroke volume of the heart is zero as blood is routed through a heart-lung machine so that the surgeons can operate on the heart vessels and aorta. Not all bypass surgeries are done this way, but many are.

Questions this figure helps answer

The figure shows a model of a healthy adult heart, and any individual's values may differ.

The model behind this figure

The curves come from a model of both sides of the heart and the circulation. Each ventricle and atrium is a chamber whose stiffness rises and falls with every cardiac cycle (a time-varying elastance), and the valves let blood flow one way. The slider scales the volume of blood available to fill the heart and vessels. Dragging point B does the same thing: the figure finds the blood volume that fills the ventricle to the volume you choose.

The figure shows the cardiac cycle after the circulation has settled at the new preload. The circulation is closed, so more filling also raises aortic pressure, and the ventricle stops ejecting at a higher volume. Across the range of the slider, end-diastolic volume goes from 90 to 142 mL, end-systolic volume from 38 to 57 mL, and the ejection fraction from 57% to 60%. The model leaves out reflexes.

At its normal settings the model gives an end-diastolic volume of 125 mL, an end-systolic volume of 51 mL, an ejection fraction of 59%, and aortic pressure of 121/78 mmHg at 75 beats per minute.

The ventricle follows the time-varying elastance model of Suga and Sagawa (Circulation Research, 1974), with the elastance curve described by Stergiopulos and colleagues (American Journal of Physiology, 1996). The same model draws the 3D pressure-volume-time loop.

Using this figure with an AI assistant

If you use an AI assistant that can see this page, whether it is built into your browser or opens the page in its own browser, you can ask it about this figure, ask it to show you what happens in a particular case, or ask it to take you through the Show Me tour. It can work the figure itself, point out its parts, and explain what you see. The rest of this section is for the assistant.

An AI assistant can use this figure in three ways. In a browser with WebMCP, the page offers its actions as tools. In the page's scripts, the same actions are in window.physiologyFigures, with a description of the control and what it means, the values shown, the model's limits, and the Show Me tour. Both do what the page's slider and handle do, wait until the figure shows the result, and return the exact values, and they can also point out parts of the figure. An assistant can also drag the slider or the handle, but then it has to read the results off the screen. The page address always holds a link to the setting shown, such as ?preload=120.