PV loop and afterload
Afterload is a measure of the resistance the heart has to overcome to eject blood, that is, the load it has to pump against; more accurately, it's the systolic wall stress of the left ventricle.
Drag point C up or down, or use the slider, to see the effect that changes in afterload have on stroke volume (SV). In general, less afterload gives greater ejection, and more afterload decreases ejection. The faded gray loop and bars show the normal cardiac cycle for comparison.
Key points
As you drag point C up or down to vary the afterload, also watch the ejection fraction (EF), shown by the colored bars and the fraction. EF is the fraction of its volume that the left ventricle ejects during one ejection. For example, if the LV fills with 150 mL of blood and ejects 75 mL of that, the ejection fraction is 50%. When you increase the afterload, the ejection fraction falls, and when you decrease the afterload, the ejection fraction rises.
At the cellular level, afterload is perhaps best thought of as the amount of force (tension) that each actin-myosin pair must generate during ventricular systole. If aortic pressure rises (e.g., as in systemic hypertension) or if the aortic outlet becomes narrowed (e.g., as in valvular aortic stenosis), each actin-myosin unit will face an increased load during ejection and will shorten to a lesser extent and at a lower velocity (prior to ventricular remodeling). These greater loads eventually lead to heart failure unless there is some form of adaptation.
In clinical terms, aortic pressure is often used as a surrogate for afterload. This is usually fine, but in certain cases aortic pressure can be a poor marker of afterload.
As an example to illustrate the previous point, consider aortic stenosis, in which the afterload created by a stenotic valve can be significant despite little change in aortic pressure. Here, the afterload is due to the narrowed valve opening, and the aortic pressure may stay relatively low because of the pressure drop across the narrowed valve. Aortic pressure is not correlated with afterload in this case.
Continuing with the example of aortic stenosis, as the ventricle adapts to aortic stenosis by thickening, actin and myosin are added and this better distributes the force and reduces systolic wall stress. As mentioned near the top, the afterload is best defined as the systolic wall stress of the LV; hence, reducing systolic wall stress is equivalent to reducing the afterload. Aortic pressure may remain unchanged throughout this process of hypertrophic adaptation; hence, this is another case where aortic pressure is not correlated with afterload.
Did you know? Concentric hypertrophy, the type of thickening of muscle that the left ventricle undergoes when faced with the high afterload of systemic hypertension or aortic stenosis for extended periods, got its name because the outline of the hypertrophied heart on chest x-ray did not appear different; the hypertrophy occurred "concentrically," that is, mainly inward, rather than making the heart appear larger.
Questions this figure helps answer
The figure shows a model of a healthy adult heart, and any individual's values may differ.
- How does high blood pressure make the heart work harder? Raise the afterload: the ventricle has to build more pressure before it can eject, and less blood leaves with each beat.
- Why do medicines that relax the blood vessels help a weak heart? Lower the afterload: the ventricle ejects more with each beat.
- What does ejection fraction mean? The colored bars show the share of the blood in the ventricle that each beat pumps out.
The model behind this figure
The curves come from a model of both sides of the heart and the circulation. Each ventricle and atrium is a chamber whose stiffness rises and falls with every cardiac cycle (a time-varying elastance), and the valves let blood flow one way. The slider scales systemic vascular resistance. Dragging point C does the same thing: the figure finds the resistance that puts C at the pressure you choose. C is where the aortic valve opens, so its pressure is the aortic diastolic pressure the ventricle has to reach before it can eject.
The figure shows the cardiac cycle after the circulation has settled at the new afterload. End-diastolic volume changes by only about 3 mL across the range of the slider, so nearly all of the change in stroke volume comes from the change in end-systolic volume. The model leaves out reflexes and the slow rise in contractility that follows an increase in afterload.
At its normal settings the model gives an end-diastolic volume of 125 mL, an end-systolic volume of 51 mL, an ejection fraction of 59%, and aortic pressure of 121/78 mmHg at 75 beats per minute.
The ventricle follows the time-varying elastance model of Suga and Sagawa (Circulation Research, 1974), with the elastance curve described by Stergiopulos and colleagues (American Journal of Physiology, 1996). The same model draws the 3D pressure-volume-time loop.
Using this figure with an AI assistant
If you use an AI assistant that can see this page, whether it is built into your browser or opens the page in its own browser, you can ask it about this figure, ask it to show you what happens in a particular case, or ask it to take you through the Show Me tour. It can work the figure itself, point out its parts, and explain what you see. The rest of this section is for the assistant.
An AI assistant can use this figure in three ways. In a browser with WebMCP, the page offers its actions as tools. In the page's scripts, the same actions are in window.physiologyFigures, with a description of the control and what it means, the values shown, the model's limits, and the Show Me tour. Both do what the page's slider and handle do, wait until the figure shows the result, and return the exact values, and they can also point out parts of the figure. An assistant can also drag the slider or the handle, but then it has to read the results off the screen. The page address always holds a link to the setting shown, such as ?afterload=120.